PERBANDINGAN BACKBONE CURVE KOLOM MENGGUNAKAN METODE PENDEKATAN PERILAKU MEKANIS, XTRACT, DAN ASCE 41-17 TERHADAP HASIL EKSPERIMEN

Authors

  • Nisrina Luthfiyah Institut Teknologi Bandung
  • William Ansel Institut Teknologi Bandung
  • Wilnando Wilnando Institut Teknologi Bandung
  • Faza Muhammad Izbik Fika Mumtaz Institut Teknologi Bandung

DOI:

https://doi.org/10.36341/racic.v9i2.4936

Keywords:

backbone curve, analytical approach method, XTRACT method, ASCE 41-17 method

Abstract

The inelastic behavior of earthquake-resistant buildings is expected to be able to withstand the cyclic loads that occur due to earthquake loads. The inelastic behavior of a building can be seen from the force-displacement curve. The curve can be obtained using several approaches, but each approach can provide different values. In this study, a backbone curve will be constructed using three approaches, namely the analytical approach, XTRACT software, and the ASCE 41-17 method. The specimen under review is a rectangular column with a single cantilever test configuration. The review parameters were the type, spacing, and area of reinforcement as well as the axial force ratio. The backbone curve obtained is compared with the experimental backbone curve. Based on the analysis, it was found that the most conservative method was ASCE 41-17. Evaluation was conducted on the three approaches used and the parameters reviewed

Downloads

Download data is not yet available.

References

ASCE 41-17: Seismic Evaluation and Retrofit of Existing Buildings

Biskinis, D. E., Roupakias, G. K., & Fardis, M. N. (2004). Degradation of Shear Strength of RC Members with Inelastic Cyclic Displacements. ACI Structural.

Choi, M.-H. & Lee, C.H. (2022). Seismic Behavior of Existing Reinforced Concrete Columns with Non-Seismic Details under Low Axial Loads.

Kim, C.-G., Park, H.-G., & Eom, T.-S. (2019). Cyclic Load Test and Shear Strength Degradation Model for Columns with Limited Ductility Tie Details. Journal of Structural Engineering, 145(2).

Li, Y.-A., & Hwang, S.-J. (2017). Prediction of Lateral Load Displacement Curves for Reinforced Concrete Short Columns Failed in Shear. Journal of Structural Engineering, 143(2). https://doi.org/10.1061/(asce)st.1943-541x.0001656

(n.d.). Jack Moehle - Seismic Design of Reinforced Concrete Buildings McGraw-Hill Professional (2014).

Narayanan, S. & Elmenshawi, A. (2009). Plastic Hinge Length of Reinforced Concrete Columns Discussion Effect of angle stiffeners on the strength and stiffness of CFS beams View project Sustainable design View project.

Pokhrel, Mandeep & Bandelt, Matthew. (2019). Plastic Hinge Behavior and Rotation Capacity in Reinforced Ductile Concrete Flexural Members. Engineering Structures. 200. 109699. 10.1016/j.engstruct.2019.109699.

Wang, J., Yang, J., & Cheng, J. (2018). Experimental Study of Seismic Behavior of High-Strength RC Columns Strengthened with CFRP Subjected to Cyclic Loading.

Zhao, X., Wu, Y., Leung, A., & Lam, H. (2011). Plastic hinge length in reinforced concrete flexural members.

Published

2024-12-30

Issue

Section

Articles