ANALYSIS OF POWER PLANT OPERATIONS TO IMPROVE EFFICIENCY USING ENERGY VALUE STREAM MAPPING (EVSM) AND FAILURE MODE AND EFFECTS ANALYSIS (FMEA) METHODS ON COMBINED CYCLE POWER PLANT UNIT AT PT PLN NUSANTARA POWER UP GRESIK

ANALISA PEMBANGKIT LISTRIK GUNA MENINGKATKAN EFISIENSI MENGGUNAKAN METODE ENERGY VALUE STREAM MAPPING (EVSM) DAN FAILURE MODE AND EFFECTS ANALYSIS (FMEA) PADA UNIT PLTGU DI PT PLN NUSANTARA POWER UP GRESIK

Authors

  • Siti Arifah Nuraini UPN Veteran Jawa Timur
  • Joumil Aidil Saifuddin UPN Veteran Jawa Timur
  • Yekti Condro Winursito UPN Veteran Jawa Timur

DOI:

https://doi.org/10.36341/rabit.v10i2.6036

Keywords:

Efficency, Gas Turbine Heat Rate, Heat Recovery Steam Gnerator, Steam Turbine

Abstract

To meet human needs, the government builds power plants with adequate capacity and quantity. In the process of electricity generation does not always run well. This study aims to improve the efficiency of the operational process by minimizing the Heat rate value that occurs in the PLTGU unit using the Energy Value Steam Mapping (EVSM) and Failure Mode And Effects Analysis (FMEA) methods. The results of the study showed that the high heat rate in Gas Turbine 1.1 and Steam turbine was caused by fouling in the Compressor Gas Turbine, Corrosion or material damage to the HP Evaporator HRSG, and leakage in the Steam Turbine condenser. The overall heat rate in the block I generating unit before the repair was 1,432.63 kcal/kwh. Then after the proposed repair projection, it was only 830.63 kcal/kwh. This means that there is a decrease in the heat rate in the operational process of 602.01 kcal/kwh or a percentage of 42.02%.

Downloads

Download data is not yet available.

References

R. M. Ratipramesti and I. A. Bangsa, “Optimization of Overcurrent Relay Protection of Kemuning Feeder at VBRA Substation at PT PLN (Persero) UP3 Bekasi UID West Java,,” J. Tek., vol. 14, no. 2, p. 83, 2022, doi: 10.30736/jt.v14i2.825.

Ardian Burhandono and N. Sinaga, “Maintaining the Reliability of the Solar Power Plant System with Method FMEA,” J. Tek. Ind., vol. 12, no. 1, pp. 30–39, 2022, doi: 10.25105/jti.v12i1.13958.

Yolnasdi, “Analysis of the Increase in NPHR Value at Unit 1 of Tenayan PLTU 2 x 110 MW,” J. Surya Tek., vol. 8, no. 1, pp. 259–264, 2021, doi: 10.37859/jst.v8i1.2629.

A. E. Wahyuni and A. Rais, “Identification of Waste in Shipping Operational Processes with VSM PT XYZ,” J. Tek. Ind., vol. 9, no. 3, pp. 161–166, 2019, doi: 10.25105/jti.v9i3.6573.

R. Anjani, “Implementation of Lean Manufacturing to Minimize Waste in Brick Production Process Using Value Stream Mapping (VSM) and Waste Assessment Model (WAM),” 2022, [Online]. Available: https://eprints.ums.ac.id/99981/

A. A. Nur, D. Sandri, N. Haidar Ahmada, and R. Aulia Purbandini, “Industrial Location Optimization With Gis-Mca: Technology Integration For In-depth Spatial Analysis,” Rabit J. Teknol. dan Sist. Inf. Univrab, vol. 9, no. 2, pp. 367–380, 2024, doi: 10.36341/rabit.v9i2.5012.

N. Mayang et al., Perbaikan Proses Produksi, vol. 4, no. 36. 2021.

N. G. Zafrullah Ismail, Abdullah Alkaff, “Reliability Analysis on Heat Recovery Steam Generator (HRSG) at PT. PJB UP Gresik using Failure Mode Effect and Criticality Analysis method ( FMECA ),” J. Tek. Pomits, vol. 1, no. 1, pp. 1–6, 2014.

D. M. Teknologi, F. Desain, K. Dan, and B. Digital, “Determination Of Gas Turbine Start Priority In Pltgu Block System,” 2020.

B. Sugandi, F. Atabiq, And R. A. Asti, “The Effect Of Gas Turbine Generator Load On The Efficiency Of Heat Recovery Steam Generator In Gas Steam Power Plant,” Elkomika J. Tek. Energi Elektr. Tek. Telekomun. Tek. Elektron., vol. 11, no. 3, p. 639, 2023, doi: 10.26760/elkomika.v11i3.639.

Sahid and Prasetiyo Budhi, “Heat Rate of Paiton Baru Steam Power Plant (Unit 9) Based on Monthly Performance Test with 100% Load,” J. Tek. Energi, vol. 12, no. 2, pp. 30–36, 2016.

I. D. Alber and B. F. T. Kiono, “Analysis of the Influence of Changes in Electricity Loading on Specific Consumption of Generation Fuel, Heat Rate and Efficiency at Unit 1 of Kendari-3 PLTU,” J. Energi Baru dan Terbarukan, vol. 3, no. 3, pp. 179–186, 2022, doi: 10.14710/jebt.2022.13371.

E. Müller, T. Stock, and R. Schillig, “A method to generate energy value-streams in production and logistics in respect of time- and energy-consumption,” Prod. Eng., vol. 8, no. 1–2, pp. 243–251, 2014, doi: 10.1007/s11740-013-0516-9.

F. R. Priyana et al., “Design of Information System and Operational Data Acquisition Based on Internet of Thing in Biogas Power Plant,” vol. 8, no. 2, pp. 7–16, 2024.

A. Khatammi and A. R. Wasiur, “Product Defect Analysis in Welding Results Using the FMEA (Failure Mode Effect Analysis) Method,” J. Serambi Eng., vol. 7, no. 2, pp. 2922–2928, 2022, doi: 10.32672/jse.v7i2.3853.

R. Ridlo, “Reducing waste in the electricity production process at the coal utility unit of PT Petrkimia Gresik with the VSM Application Dan Fmea,” 2020.

Downloads

Published

2025-07-10

How to Cite

[1]
S. A. . Nuraini, J. A. Saifuddin, and Y. C. Winursito, “ANALYSIS OF POWER PLANT OPERATIONS TO IMPROVE EFFICIENCY USING ENERGY VALUE STREAM MAPPING (EVSM) AND FAILURE MODE AND EFFECTS ANALYSIS (FMEA) METHODS ON COMBINED CYCLE POWER PLANT UNIT AT PT PLN NUSANTARA POWER UP GRESIK : ANALISA PEMBANGKIT LISTRIK GUNA MENINGKATKAN EFISIENSI MENGGUNAKAN METODE ENERGY VALUE STREAM MAPPING (EVSM) DAN FAILURE MODE AND EFFECTS ANALYSIS (FMEA) PADA UNIT PLTGU DI PT PLN NUSANTARA POWER UP GRESIK”, rabit, vol. 10, no. 2, pp. 193–203, Jul. 2025.

Issue

Section

Articles

Similar Articles

> >> 